Estimate the annual electricity cost of compressed air leaks from leak flow and specific power.
This is the standard method used in compressed air energy audits to put a rupee value on air leaks: leak flow is converted to power using the compressor's specific power, then multiplied by operating hours and electricity rate. It is a common way to justify leak-repair programs to management.
Given: A leak survey estimates 10 CFM of leakage, on a compressor with specific power 20 kW/100 CFM, running 4000 hours/year at ₹8/kWh.
Result: Leak power = 20 × (10÷100) = 2 kW. Annual cost = 2 × 4000 × 8 = ₹64,000 per year — from leaks alone.
Industry studies commonly cite 20–30% of compressed air generated in an average industrial plant being lost to leaks in untreated systems, making leak audits one of the highest-return energy-saving activities available.
One common method: run the compressor with all air-consuming equipment switched off, and measure how long it takes to load and unload; the load fraction times compressor FAD gives an approximate leak flow.
These calculators are provided for informational and estimation purposes. Results depend on the assumptions and input values used. Always verify critical engineering calculations against applicable standards, manufacturer specifications, site measurements, and qualified professional advice.